Photo Stability Chamber

Photo Stability Chamber

"Classic Scientific" make Photo Stability chamber is design to suit standards for photogenic effect along with temperature & Humidity for not less than 1.2 million Lux hours and ultra violet source of energy for not less than 200 watts hours/sqm As per ICH & CGMP guidelines.

Range :

  • Temperature range : 10 °C. To 40 °C
  • Temperature Accuracy : +/- 0.5 °C
  • Temperature Uniformity : +/- 1 °C
  • Humidity range : 40 % r.h. to 80% r.h.
  • Humidity Accuracy : +/- 2% r.h.
  • Humidity Uniformity : +/- 3% r.h.

Application :

PHOTO STABILITY CHAMBER are used for studies related to Photogenic effect on the samples exposed to U.V. & day light illuminations. It is design to create Nature Climatic conditions with the help of Dry air, refrigeration & Humidity system built-in. This Chambers are basically in application with Pharmaceuticals, & also Electro-mechanical R&D test to confirm the successful result of the product under test.

Construction :

Photo Stability Chambers are constructed with highly Insulated "PUF" or Glass wool insulation. The body is either galvanized or stainless steel 304 quality, where as inner is 304 S.S. Door flush type with full size glass door for viewing inside objects with silicon gasket & locking arrangement.

Documentation :

Provided with DQ, IQ, OQ, PQ protocol & Validation report.


Models CS-90a CS-90b CS-90c CS-90d
Chamber Volume 90.0 ltrs 170.0 ltrs 285.0 ltrs 340.0 ltrs
Cubic Feet 3 6 10 12
Internal Size cms. 40 X 40 X 57 50 X 40 X 85 57 X 57 X 88 60 X 60 X 95
External Size cms. 53 X 68 X 135 63 X 68 X 163 70 X 85 X 166 73 X 88 X 173
Shelves 2 2 3 3
Range + 10 °C to 40 °C
Controller Accuracy +/-0.1 °C of set Value for Temp / + /- 2 % (Humidity)
Uniformity +/- 0.5 °C for Temp. +/- 3 % for Humidity
Photogenic effect Ultra Violet wavelength 365nm. (measured in hours/square meter) Florescent light 4 nos. of >200 watts (measured in Lux).
Heat up Time 30 min. up to 4 °C without load
Cool Down time 15 min. upto + 10 °C without load
Cooler Plate Fin Cooler
Compressor Hermetically Sealed Brand New Kirloskar Compressor
Controller Microprocessor based programmable P.I.D controller
Sensor Pt-100 for Dry & Wet Bulb / Capacitor type for Humidity
Internal Chamber Stainless Steel 304 / 316L quality
External Stainless Steel Matt Finish / Mild Steel Powder Coated
Body Insulation Puf 50mm / Glass Wool 65mm
Door Insulation Thermo Cole
Inner Glass Door Inner Full Size Sea through Acrylic 8 mm thick
Forced Air Draft 7" Tangent Flow by Aluminium blower
Air Circulation Motor 1/12 Hp, 1440 R.P.M.
Steam Injection System I.S.I. Mark Kettle Heater / Ultrasonic Humidifier
Water tank Cartridge Reservoir 4 ltrs 4 ltrs 9 ltrs 9 ltrs
Water tank Cartridge Boiler 4 ltrs 4 ltrs 9 ltrs 9 ltrs
Water quality pH 6.2 to 7.2
Safety Device Water Level alarm, over heating or humidity soft alarm
Optional
Imported Sensor 0 to 100% R.H., Accuracy of +/- 2%
Data Acquisition 21 CFR part 11 compliance
Computer Interface RS 485 / RS232 interface for multiple & single communication port
Safety device Thermostat or Energy Regulator
Cyclic Timer 0 to 24 hrs X 7 days cyclic ON / OFF timer for illuminating condition
Capacity (watts) 2000 2750 3250 3750
Power Consumption 9 amps 12 amps 14 amps 17 amps
Electric requirements AC 230 V & 50 Hz cycle.
Request A Quote

Leading manufacturer of Laboratory and Scientific Equipments

TOP